Power supply |
230V AC ± 10%, 45...63 Hz, 50VA |
Device fuse |
1.0 A M (medium slow-blow) |
Measurement method |
Luminance L20 according to DIN 67524 or CIE-88 |
Maximum measurement range |
0....10,000 cd/m² |
Minimum measurement range |
0......1,000 cd/m² |
|
Please specify the desired measurement range when ordering.
Other measurement ranges available upon request.
Calibration to the measurement range is only possible at the factory! |
Measurement signal |
4.0...20.0 mA |
|
Load < 250 Ω |
Measurement signal fuse |
32 mA M (medium slow-blow) |
Interference protection |
Mains input with mains filter, sensor output with fine fuse and suppressor diode |
Electrical connections |
Spring clamp terminals for wire cross-sections 0.5...2.5 mm² |
|
|
Optical properties |
|
Field of view |
Adjustable between 16.5° to 31° (adaptable to local conditions) |
Varifocal lens |
Focal length: 75...300 mm, adjustable 75...135 mm |
|
|
Physical properties |
|
Housing |
Stainless steel (W. Nr.: 1.4571), double-walled
Requirement class I according to ZTV-Ing. Part 5, Section 4 |
Cable entry |
2 x M25 cable glands for cables with outer diameter 10…15 mm |
Dimensions |
Housing without swivel base L × W × H = 455 × 175 × 185 mm
Housing with swivel base L × W × H = 455 × 175 × 245 mm |
Protection class |
IP65 |
Weight |
9.5 kg |
Temperature range |
Ambient temperature: -30°...+70°C
Storage temperature: -30°...+70°C |
Installation position |
Clearance above the camera > 250mm
Clearance behind the camera > 500 mm |