5. SECTION SENSORS (Tunnellighting)
 

  Productsearch:  

Categories

5.1 LUMINANCE METER LUCI L 20

5.2 LUMINANCE METER OF LUCAS L 20

5.3 LIGHTING STRENGTH METER LUXA EV

5.4 LIGHTING STRENGTH METER LUXA EH

5.5 LUMINANCE METER LUCI Neo

5.6 LUMINANCE METER LUCI SL



Click to see a larger image
(Illustration similar)
 

5.5.2 ESPLUCINeo – „LUMINANCE METER LUCI NEO“ EN

Information
  • Sensor for the luminance of the tunnel environment
  • Image support of the proven analog sensor
  • Measurement method: Integral luminance according to CIE-L20 or RABT (EABT) / DIN 67524
  • Long-term stable amplifier, high reliability
  • Vario optics for field-of-view adjustment
  • Precise adaptation to the spectral sensitivity of the human eye, V(λ)
  • Electronically controlled heating to prevent icing
  • The front glass is effectively protected against contamination by a special aperture ring using the air stagnation effect
  • Fault message output via potential-free contact for collective notification in case of temperature/signal error
  • Up to two separate measurement channels with individual measurement ranges (e.g. 0…1,000 and 0…10,000 cd/m²)
Advantages
Remote control of the sensor’s alignment, ensuring traffic safety and energy efficiency
  • Detection of measurement interference sources (also remotely during operation via software)
  • On-site adjustable field of view, allowing local adaptations
  • Optimal adaptation of the sensor to the driver’s perspective, increasing safety
  • LAN and WLAN connection for data transmission
  • Video image accessible from all current operating systems via standard web browser

Technical data
Electrical properties
Power supply 230V AC ± 10%, 45...63 Hz, 50VA
Device fuse 1.0 A M (medium slow-blow)
Measurement method Luminance L20 according to DIN 67524 or CIE-88
Maximum measurement range 0....10,000 cd/m²
Minimum measurement range 0......1,000 cd/m²
  Please specify the desired measurement range when ordering.
Other measurement ranges available upon request.
Calibration to the measurement range is only possible at the factory!
Measurement signal 4.0...20.0 mA
  Load < 250 Ω
Measurement signal fuse 32 mA M (medium slow-blow)
Interference protection Mains input with mains filter, sensor output with fine fuse and suppressor diode
Electrical connections Spring clamp terminals for wire cross-sections 0.5...2.5 mm²
   
Optical properties  
Field of view Adjustable between 16.5° to 31° (adaptable to local conditions)
Varifocal lens Focal length: 75...300 mm, adjustable 75...135 mm
   
Physical properties  
Housing Stainless steel (W. Nr.: 1.4571), double-walled
Requirement class I according to ZTV-Ing. Part 5, Section 4
Cable entry 2 x M25 cable glands for cables with outer diameter 10…15 mm
Dimensions Housing without swivel base L × W × H = 455 × 175 × 185 mm
Housing with swivel base L × W × H = 455 × 175 × 245 mm
Protection class IP65
Weight 9.5 kg
Temperature range Ambient temperature: -30°...+70°C
Storage temperature:          -30°...+70°C
Installation position Clearance above the camera > 250mm
Clearance behind the camera > 500 mm
 
To the Flyer: (click)
To the Instructions: (click)