Kontakt DE
 
  BACK       FORWARD  
2.1 LIGHTCONTROL LUMATICX LEVELCONTROL
 

  Productsearch:  


Click to see a larger image
(Illustration similar)
 

2.1.2 ESPTIX1R80 – „Light controller LUMaticX, gradational-control, 1 entrance-lighting“ EN

Product description
  • Light controller for activating and controlling entrance lighting
  • Stepped control with up to 8 steps according to the luminance difference method
  • Processing of 1 x luminance value L20 (outer field)
  • Processing of 1 x luminance value Lth (threshold zone)
  • Ready assembled on mounting plate for installation in control cabinets
Hardware basic equipment including
  • Control-, visualization- and communication-processor
  • Touchpanel (1024x768, 15")
  • 256 KByte RAM
  • Real-time clock
  • Digital-IN 32 channel, digital-OUT 32 channel (optional expandable)
  • Analogue-IN 4 channel 16 Bit, analogue-OUT 4 channel 12 Bit (optional expandable)
  • Diagnostic module for control voltage 24 V
  • 8 hardware fault messages (optionally expandable)
  • 1 x bistable relay module 8-fold (optionally expandable)
  • Overvoltage protection and isolating amplifier
  • CPU external DC 24 V / 5 A power supply
  • Profibus-DP Master
Software basic equipment including
  • Operating system, system software and all necessary licenses
  • Basic visualization package (overview, details, parameters, manual legend, message system with 32 messages, energy: single-line diagram of light control, optionally expandable)
  • Simulation mode (hand / operator)
  • Switchable measuring method (CIE-88 / RABT 2006 / DIN 67524)
  • User management with password hierarchy
  • Online language switching
  • Direction-dependent external special-operation inputs (event fire / full lighting / service-maintenance / control via SCADA / optionally extendable)
  • Sensor redundancy programs
Your advantages
  • Adjustment of the luminance of the threshold and transition zone to the outer field
  • Activation of the day stages subject to the luminance on the lane of the threshold zone
  • Automatic adjustment of the luminance to the actual needs
  • Energy savings through compensation of planning reserves
  • Safety gain through autotracking in case of decrease of luminous flux (e.g. lamp ageing)
  • Ageing of the lamps, pollution of the luminaires and changing reflection properties of the tunnel walls and the road are compensated by the lighting control system, as far as this is possible.

Technical specifications
Electrical properties
Voltage supply 230V AC ± 10%, 45...63 Hz
max. ca. 300 VA (light controller) + 80 VA (external Sensors L20 and Lth)
Device fuse Circuit breaker 3 x B16A
Note selectivity when dimensioning the pre-fuse!
Measuring method Luminance L20 according RABT, DIN 67524 or CIE-88 (switchable)
Measuring inputs 2 × analogue value (1 × outer field L20 / 1 × threshold zone Lth)
Measuring signals 4,0...20,0 mA
Overvoltage protection 2-fold overvoltage protection modules (optionally expandable)
Galvanic  isolation Analogue signals via isolation amplifier
Binary signals via coupling relays
Electrical connections Spring-cage terminals for wire cross-sections 0.5...2.5 mm²
   
Physical properties  
Housing Light controller pre-mounted on hot-dip galvanized mounting plate
Dimensions B × H ×  D =  699 × 1 896 × 150 mm
Protection degree IP 20
Weight ca. 25 kg
Temperature range Ambient temperature:     0°...+60°C
Storage temperature:  -30°...+70°C
Mounting position Vertical, for installation in control cabinets with W x H = 800 x 2 000
Project specific execution on request

To the accessories: (click)
 
To the Instructions: (click)

Click to see a larger image
(Illustration similar)
 

2.1.4 ESPTIX2R80 – „Light controller LUMaticX, gradational-control, 2 entrance-lightings“ EN

Product description
  • Light controller for activating and controlling entrance lighting
  • Stepped control with up to 2 x 8 steps according to the luminance difference method
  • Processing of 2 x luminance value L20 (outer field)
  • Processing of 2 x luminance value Lth (threshold zone)
  • Ready assembled on mounting plate for installation in control cabinets
Hardware basic equipment including
  • Control-, visualization- and communication-processor
  • Touchpanel (1024x768, 15")
  • 256 KByte RAM
  • Real-time clock
  • Digital-IN 32 channel, digital-OUT 32 channel (optional expandable)
  • Analogue-IN 4 channel 16 Bit, analogue-OUT 4 channel 12 Bit (optional expandable)
  • Diagnostic module for control voltage 24 V
  • 8 hardware fault messages (optionally expandable)
  • 2 x bistable relay module 8-fold (optionally expandable)
  • Overvoltage protection and isolating amplifier
  • CPU external DC 24 V / 5 A power supply
  • Profibus-DP Master
Software basic equipment including
  • Operating system, system software and all necessary licenses
  • Basic visualization package (overview, details, parameters, manual legend, message system with 32 messages, energy: single-line diagram of light control, optionally expandable)
  • Simulation mode (hand / operator)
  • Switchable measuring method (CIE-88 / RABT 2006 / DIN 67524)
  • User management with password hierarchy
  • Online language switching
  • Direction-dependent external special-operation inputs (event fire / full lighting / service-maintenance / control via SCADA / optionally extendable)
  • Sensor redundancy programs
Your advantages
  • Adjustment of the luminance of the threshold and transition zone to the outer field
  • Activation of the day stages subject to the luminance on the lane of the threshold zone
  • Automatic adjustment of the luminance to the actual needs
  • Energy savings through compensation of planning reserves
  • Safety gain through autotracking in case of decrease of luminous flux (e.g. lamp ageing)
  • Ageing of the lamps, pollution of the luminaires and changing reflection properties of the tunnel walls and the road are compensated by the lighting control system, as far as this is possible.

Technical specifications
Electrical properties
Voltage supply 230V AC ± 10%, 45...63 Hz,
max. ca. 300 VA (light controller) + 80 VA (external Sensors L20 and Lth)
Device fuse Circuit breaker 3 x B16A
Note selectivity when dimensioning the pre-fuse!
Measuring method Luminance L20according RABT, DIN 67524 or CIE-88 (switchable)
Measuring inputs 4 × analogue value (2 × outer field L20 / 2 × threshold zone Lth)
Measuring signals 4,0...20,0 mA
Overvoltage protection 4-fold overvoltage protection modules (optionally expandable)
Galvanic  isolation Analogue signals via isolation amplifier
Binary signals via coupling relays
Electrical connections Spring-cage terminals for wire cross-sections 0.5...2.5 mm²
   
Physical properties  
Housing Light controller pre-mounted on hot-dip galvanized mounting plate
Dimensions B × H ×  T =  699 × 1.896 × 150 mm
Protection degree IP 20
Weight ca. 28 kg
Temperature range Ambient temperature:     0°...+60°C
Storage temperature:  -30°...+70°C
Mounting position Vertical, for installation in control cabinets with W x H = 800 x 2 000
Project specific execution on request

To the accessories: (click)
 
To the Instructions: (click)

 1 to 2 out of 2  [ <<  1  >> ]